An investigation into cracking of the beta alumina during cell assembly resulting from incomplete contact of the sealing surfaces (IM-MS-023)

Last updated on 12 July 2013 2:12
Recent examination of failed BR 16 cells has shown a circumferential crack to be present in the beta alumina adjacent to the compression seal in about 7% of cells assembled. Although various electrical and chemical mechanisms have been proposed to explain these observations, it was decided to see if a...
Author(s): Seeds A.D.
Organisation(s): British Rail Research ;
1977
United Kingdom