The measurement of stress levels in the POP-train articulation joint (IM-SI-030)

Last updated on 03 December 2013 9:24
Strain-gauge measurement of dynamic stresses in the laboratory and at the Old Dalby test track have shown high stresses, giving a limited fatigue life for the component of about 2x10° cycles.
Author(s): Cahill J.
Organisation(s): British Rail Research ;
1971