The efficiency of the safety groove on cast iron cylinder covers (continued) (E-048)

Last updated on 13 December 2013 2:33
As indicated in Report No. E.19 the bursting pressure of the present design of cylinder cover is 650 lb./sq.in. In Report E.3 it was found that the maximum pressure which could be supported by the piston was 800 lb/sq.in, thus showing that the safety groove did not fulfil its purpose.
Author(s): Banks LB
Organisation(s): British Rail Research ;
1953
United Kingdom