Full scale fire tests on railway vehicles. 3.1 Mk. III Sleeping Car: Structural fire resistance (TM-HAZ-13)

Last updated on 02 April 2014 12:44
The Structural Fire Resistance of the Mark III Sleeping Car has been tested by allowing the largest imaginable, accidental fire to develop in one berth. A two-berth module, which included one complete fire compartment, was built for the test. The stability of the structure remained intact throughout the test.
Author(s): Davies PG;Wheatley AR;Morris VC
Organisation(s): British Rail Research ;
1985
United Kingdom