Determination of air duct sizes and positions for a 9-module trailer coach (IM-APT-287)

Last updated on 24 July 2014 4:10
1. This memorandum shows the derivation of the statements made earlier in Report No IMAPT 286. The criteria and assumptions adopted are listed in Appendix 1. The detailed calculations are collected together in Appendix 2. 2. The total air in circulation is determined by the amount of heat to...
Author(s): Tomlinson B.A.
Organisation(s): British Rail Research ;
1968