Menu

GERT8000-HB12 Iss 9

Duties of the engineering supervisor (ES) or safe work leader (SWL) in a possession

Synopsis

You will need this handbook if you carry out the duties of the ES or SWL in a possession.

Summary Of Changes

It is no longer permitted for work in connection with isolations of the AC or DC electrification systems to begin before the work-site marker boards are in position, and the wording in section 3.3 has been changed to remove reference to this being allowed. It has also been reworded to make it clear that no other work can commence within the work site until the person in charge of the possession (PICOP) has told the ES that the work site has been granted.

Section 6.9 is a new section describing the actions necessary when a controller of site safety (COSS), designated person (DP) or machine controller (MC) requests line protection for work to be carried out on a rail vehicle.

Section 7.8 has been renamed ‘manually controlled level crossing’ to remove gender-specific language.

Optional reading and resources:

Standards quarterly webinar - September 2022

Read full standard
register-icon
Registered
Live
Rule Book Handbook
Issued:
03/09/2022
Published:
03/09/2022
In Force:
03/12/2022
Next Review:
03/12/2023

Details

Consultation Status Closed
Vehicle Assessment No
Supersedes GERT8000-HB12 Iss 8
Lead Committee Traffic Operation and Management - TOM
Supporting Committee Control Command and Signalling - CCS; Rolling Stock - RST; Plant - PLT
Impact Assessments
register-icon
Registered
22 IA16
Supporting Documents GERT8000-RBBL Iss 38 ; GERT8000 Issue HB Iss 16
Deviations
register-icon
Registered
24-019-DEV

Manchester Piccadilly Station Emergency Glass Roof Repairs

24-004-DEV

The use of secondary protection for T3 possessions

22-101-DEV Revised 05-03-2024

The use of signal disconnection as secondary protection for T3 possessions - National Deviation

23-027-DEV

Additional Protection for Protection Zones

22-101-DEV Revised 13-12-2023

The use of signal disconnection as secondary protection for T3 possessions

23-040-DEV

Possession Optimisation - enabling clearer safety communications in possessions through web-enabled devices

23-020-DEV

Deviation; rule book

22-101-DEV Revised 03-07-2023

The use of signal disconnection as secondary protection for T3 possessions

21-054-DEV Revised 12-05-2023

Birmingham New Street station area: Requirement to work within 100 metres of the Work Site Marker Boards (WSMB) where there is no more than a 10 mph permissible speed limit.

22-113-DEV Revised 14-02-2023

Isolation COSSs being briefed and signing in with the Engineering Supervisor within ES work site - deviation against 'Setting up the work site' requirement

22-101-DEV Revised 09-02-2023

The use of signal disconnection as secondary protection for T3 possessions

22-113-DEV

Isolation COSSs being briefed and signing in with the Engineering Supervisor within ES work site - deviation against 'Setting up the work site' requirement

22-101-DEV

The use of signal disconnection as secondary protection for T3 possessions